TWR Nov 2026_ebook - Flipbook - Page 42
INDUSTRY COMMENT|WATER EFFICIENCY
INDUSTRY COMMENT
Phill Mills is chair of
the UK Water Retailer
Council, director of Policy
Consulting Network and
a member of the Water
Efficiency Campaign
Stakeholder Group.
New buildings and fittings
THE ELEPHANT IN
THE (WASH)ROOM
What about new installations?
Using AI to review different growth
scenarios out to 2038 suggests a
range of new urinal installations from
8,000 to 12,000 each year. There will
also be refurbishments; AI analysis
suggests up to 75,000 urinals could
be replaced each year. Together,
that’s 85,000 potential new urinals in
England each year.
Taking a more efficient water use
isms within the urinal trap to prevent
figure per urinal of 50,000 - 80,000 l/y
build-up of deposits and fats in the
(which ties in with the Water Supply
waste pipework, along with a spe(Water Fittings) Regulations 1999 recial valve to prevent odours coming
quirement of the associated cistern
back from the connected drain/
filling at no more than 10 litres/hour)
sewer. So as long as instruction is
means these new flushing urinals
provided to cleaning and maintewill each continue to use between
nance teams, there isn’t a
140-220 l/day. For the 85,000
smell problem.
new or replacement
installations, that
Replacement
equates to 12-18 Ml/d
– potential water
programmes
saving from replac- that could potentially
Comprehensive
be made available
ing 10% of urinals
with waterless
replacement
for other purposes.
ones
programmes offer
If we compare that
great potential reward.
with household use, that
Replacing 10% of existing urinals
volume could supply between
with waterless ones could deliver
36,000 and 56,000 new homes.
water savings of around 18,500Ml/y
or 51Ml/d. That’s around 20% of the
Address the elephant
Government’s 9% non-household
So my question is: why – when there
reduction target (245Ml/d).
is an alternative non-water using
This could be achieved without
technology available – is it still
any changes to how businesses
acceptable to continue to rely on
use water in their production proa legacy design that flushes away
cesses. so the intervention would
very significant volumes of treated
have minimal impact on business
drinking water every day?
operations, and leave further opIt’s now time to address that elportunities for savings in process
ephant in the washroom and make
water for the taking.
the change. TWR
Phill Mills points out that replacing 10% of urinals
with waterless versions could meet 20% of the nonhousehold demand reduction target for 2038.
Demand reduction is expected to
deliver 48% of the 5bn litre a day
supply gap forecast by 2050. In the
non-household sector, the Government has set a target for a 9%
reduction by 2038 and 15% by 2050,
against a 2019/20 baseline.
Encouraging water efficiency typically reaches into the realms of dual
flush toilets, spray taps and lower
flow shower heads. But we seem to
have overlooked a key point: what
about products that could still function as intended, but use no water?
Urinals are common features
of public, commercial, educational, institutional, and industrial
washrooms. Modern urinals should
be fitted with controls – sensors or
timers to reduce water use and/or
hours of operation – so not flushing
when premises are closed. However, from analysis following retrofits,
currently installed urinals generally
flush away around 100,000 litres
of treated drinking water a year.
That’s equivalent to 274 litres/day,
so around the same as used by a
two-person household. Many newer
installations will use less than that –
42
November 2026
around 50,000-80,000litres/year, but
poorly calibrated or uncontrolled
systems can use 200,000-300,000
litres/year.
The scale of the problem?
Unfortunately there is no data (that
we could find) on the overall number
of urinals installed in England. But AI
analysis of available data suggests a
range of 1.5 – 3.1 million, with 1.85m
the lowest best estimate. Assuming
use of 100,000l/y per urinal gives a
total use figure of 185,000 megalitres
per year (Ml/y) – or 507Ml/d – used by
flushing urinals. That is the elephant in
the washroom.
But it can be addressed. No flush
versions that use no treated water
are available and the average payback period for a waterless urinal
retrofit programme is generally only
12-18 months.
That said, waterless urinals do
have their critics – who mainly cite
smell. This is in almost all cases due
to the wrong cleaning / maintenance regime, which treats them
as ‘standard’ water flushing urinals.
Waterless ones rely on microorgan-
51Ml/d
THE UK WATER REPORT